Comfort system ja 60 инструкция

User instructions of JA-60 „Comfort»

1. Indicators

Alarm

alarm triggered by an intruder, smoke, gas etc.

Tamper

opened cover, damaged detector, excessive number of attempts to enter code etc.

Fault

power loss, lost communication with a detector etc., (confirm pressing key N)

Battery

battery of the device specified on the display is low. See battery replacement section.

Armed

continues = armed, slow blinking = exit delay, fast blinking = entrance delay

Power

continues = AC power & back-up battery are O.K., blinking = failure (AC power or back-up

battery), off = control panel is not powered

Two digits display

Specifies event source or mode of the control panel.

event sources:

1 to 16 zone input number

c1 to c8

wireless controller or keypad number

C

control panel

A

wireless siren

J

sub system (other JA-60 or 65 system enrolled)

L

telephone line

d

digital line (PC interface, keypad JA-60E, …)

F

wireless communication of the keypad lost (JA-60F only)

control panel modes:

P

programming mode

U

user mode (bypass setting, testing, battery replacement, voice dialer setting)

H

home (partial) arming (inputs & wireless detectors addressed to B section are bypassed)

section A arming (split system)

section B arming (split system)

a zone is bypassed when arming

waiting for more data to complete entry

2. Access codes

The control panel can be operated with the following codes (by JA-60E or JA-60F keypad or via connected

PC):

Master code

is an extra user code, which can be used for arming, disarming but also for code changes, entering of user mode,

bypass setting, system testing, battery replacement, voice dialer programming (if enabled by installer) — factory default

Master code is 1234.

If the system is split, the use of MC will arm all sections if no section is armed or it will disarm all sections if any is

armed. If no code arming is disabled and the system is spilt then entering F1 MC will effect only section A and

entering F2 MC will effect only section B.

User codes

up to 14 different user codes can be set in the system for different users for arming and disarming only (all are blank

from the factory). This way it is possible to differ between different users operations (details about used codes are

stored in the control panel internal events memory, the Comlink software or the monitoring station can access these

details).

Service code

is a code for installer to open programming mode for the control panel setting and testing (entering F 0 Service code).

If the control panel is split, the user codes can be addressed to sections A or B in the programming mode.

Note: After 5 attempts to enter an invalid code a tamper alarm is triggered, indicated by LED «Tamper» and «C» on the display.

3. Controlling the system

Arming

enter your access code or press the A button on the remote control. System will beep and will start exit delay count

down. You must leave the protected area during the exit delay.

Disarming

enter your access code or press the B button on the remote control. The panel will beep twice and will disarm. When

you enter the protected area before disarming, the entrance delay count down will start. If disarming is confirmed

with three beeps, check the keypad indicators for information (alarm memory, failure, low battery etc.).

To stop alarm

enter your access code or press the B button on the remote control.

Panic alarm

entering F 7 before your code will trigger a silent panic alarm. This can also be triggered by the RC-22 panic button

or by pressing and holding of both buttons of the RC-11 remote control for 3 seconds.

User instructions of JA-60 «Comfort»

— 1 —

MDY51410

Предложите, как улучшить StudyLib

(Для жалоб на нарушения авторских прав, используйте

другую форму
)

Ваш е-мэйл

Заполните, если хотите получить ответ

Оцените наш проект

1

2

3

4

5

Table of Contents for jablotron JA-60 «Comfort»:

  • 13. Monitoring station reporting codes table A two digit reporting code rc (00 to FFh) can be set for every event. If 00 is programmed as a report code, that event will not be reported. The major events group is marked with Rc. When formats 3/1 or 4/1/1 are used, only these major events are reported to the Monitoring Station. This makes it necessary to only program the R digits. The second digit does not count. For Contact ID protocol, program code 11 for major events (Rc) which you want to report and the system will generate all det

  • 2.5 Connection of the telephone line (only for models with an optional built in dialer) • Use the provided telephone cable to connect the telephone line to the IN jack inside the control panel (see fig. 4), • Connect any telephone, fax or other phone operated device to the OUT jack, marked with a phone symbol • When the control panel is in normal stand by mode, the phone line and any attached device will operate as normal. The dialer can be connected only to a

  • Fig. 9 A. Attach the bracket with the two provided screws, being sure that the arrow inside the bracket is pointing up. We recommend to install one screw in the pre-punched hole on the lever of the tampering sensor (see fig. 9. A). The second hole can be easily punched out from the pre-formed holes. Tighten the screws firmly, being sure that the bracket is not crooked. Alarm system JA-60 «COMFORT» — 7 — MDY51319 B. Click on the complete detector (including cover) . Both tabs must click. Check that the detect

  • Alarm system JA-60 «COMFORT» — 23 — MDY51319 12. Monitoring station communication setting This part of the manual is intended only for the use of specialists involved in monitoring. We recommend to use a com- puter equipped with Comlink program for complete setting of the monitoring station communication (see 14). Changes of the setting can also be performed manually using the JA-60E or built in keypad of the JA-60 system: • Enter the programming mode (entering F 0 SC — SC = Service Code, factory default SC=6060),

  • JA-60G Gas leak detector — triggers a Fire alarm when any combustible gas is detected (natural gas, city gas, propane, butane etc.). The detector is powered directly form the AC power network and it wirelessly transmits information to the control panel. The JA-60G has a built in siren and an output relay. The relay, for example, can be wired to an electrical valve to turn off the gas supply when a leak is detected. power 230V(+10 to -15%) / 50Hz, about 2W 2 sensitivity levels: 10% and 20% of LEL (calibrated for Methane)

  • Alarm system JA-60 «COMFORT» — 17 — MDY51319 8.20. Wireless siren alarm sequence: 3 8 x The wireless siren alarm function can be disabled with this parameter. This setting will have no influence on the outdoor siren chirp sounds function if enabled in the siren. options: 3 8 1 siren enabled 3 8 0 siren disabled Factory default setting: siren enabled 8.21. Indication of system problems when arming sequence: 3 9 x The system re

  • built in buzzer. Illuminated keys can be covered with a closeable cover. The keypad has TWO-WAY communication with the control panel and it is enrolled as a controller (positions c1 to c8). Multiple JA-60F keypads can be enrolled to a single control panel. power 3 V = , 5 0 µ A / 100 mA (2x AAA battery 1,5V) battery life time about one year communication range max. 100 m (open area) working environment indoor use (-10 to +40 °C) optional AC adapter 12V ss/100mA (permanent keys illumination with th

  • Alarm system JA-60 «COMFORT» — 25 — MDY51319 12.5. Phone number entering sequence: 06 Monitoring station modem phone numbers can be stored by entering the following sequence: 0 6 x x …. x F y xx…x — Monitoring Station phone number (up to 16 digits) y is 1 for main phone number memory 2 for back up phone number memory Pause (3 sec.) can be inserted into the telephone

  • 14. Personal Computer Interface with JA-60 The JA-60 system can be connected to a Personal Computer (PC) locally, using the PC-60A interface cable. It is also possible to dial into the system from a remote PC (or the JA-60E keypad) using the JA-60U modem (see 15). Comlink software is available for Win- dows system. User can check and operate the JA-60 system easily via their PC, can read complete events memory with all details, can view the map of the installation (seeing topical triggering of the detectors) etc. H

  • Alarm system JA-60 «COMFORT» — 16 — MDY51319 8.15. Exit delay audible indication sequence: 3 3 x The exit delay can be indicated by the „beeping“ of the control panel (for the last five seconds, the beeping is faster). The audible indication can be disabled with this setting. options: 3 3 1 indication enabled 3 3 0 indication disabled Factory default setting: indication enabled 8.16. Partial arming exit delay audible indication sequence: 3 4 x Partial arming with F2 provides an exit delay for delayed reaction

  • Alarm system JA-60 «COMFORT» — 15 — MDY51319 options: 2 8 1 reset enabled 2 8 0 reset disabled Factory default setting: reset enabled Note: if the Master or Service code is forgotten when the reset is disabled, the reset of the control panel will be possible only by the manufacturer. 8.11. Enrollment of the control panel to a UC-216, 222, JA-60K etc. sequence: 2 9 9 The control panel can

  • Alarm system JA-60 «COMFORT» — 13 — MDY51319 8.2. Enrollment (teaching) of wireless items enter: 1 As a maximum 16 detectors and 8 controllers (remote controls & keypads) can be enrolled to the control panel. A wire- less siren and an additional JA-6x control panel (subsystem) can be enrolled as well. • press key 1 (while „P“ is displayed) to enter the enrolling mode. The control panel will display the next free position to enroll a detector. •

Questions, Opinions and Exploitation Impressions:

You can ask a question, express your opinion or share our experience of jablotron JA-60 «Comfort» device using right now.

[Page 1] jablotron JA-60 «Comfort»

JA-60 “COMFORT” Alarm system Installation manual

[Page 2] jablotron JA-60 «Comfort»

[Page 3] jablotron JA-60 «Comfort»

Contents: 1. Before starting 4 2. Control panel installation 4 2.1. Opening of the control panel 4 2.2. Attaching the control panel to the wall 4 2.3. Antenna installation 4 2.4. Connection of the AC adapter 4 2.5 Conne…

[Page 4] jablotron JA-60 «Comfort»

Thank you for purchasing a Jablotron alarm system. Its reliable operation depends on proper installation. We recom- mend having this alarm professionally installed. To find a qualified installer, please contact your Jablotron Distributor. The manufa…

[Page 5] jablotron JA-60 «Comfort»

2.5 Connection of the telephone line (only for models with an optional built in dialer) • Use the provided telephone cable to connect the telephone line to the IN jack inside the control panel (see fig. 4), • Connect any telephone, fa…

[Page 6] jablotron JA-60 «Comfort»

opening of door detector (bottom view) • Open the detector’s cover by pressing the internal pawl – see fig. 7 • Install the detector to the desired location using the two provided screws. • Be sure that the antenna is vertical (p…

[Page 7] jablotron JA-60 «Comfort»

Fig. 9 A. Attach the bracket with the two provided screws, being sure that the arrow inside the bracket is pointing up. We recommend to install one screw in the pre-punched hole on the lever of the tampering sensor (see fig. 9. A). The second…

[Page 8] jablotron JA-60 «Comfort»

5. Testing of detectors and controllers The control panel should be in the programming mode for testing – (LED display will show „P“ )(see part 8. how to enter programming mode). If the control panel will not indicate a detector’s trigg…

[Page 9] jablotron JA-60 «Comfort»

5.4. Recording a detector’s location Alarm system JA-60 «COMFORT» — 9 — MDY51319 After successfully testing all detectors, we recommend that you record the location of the sensors directly on the control panel (area under the LED …

[Page 10] jablotron JA-60 «Comfort»

7. Wiring of external devices In addition to using wireless items, which are part of the JA-60 system, hard wired devices can be wired to the system. The JA-60 control panel (JA-60K) and the JA-60N detector are both equipped with terminals f…

[Page 11] jablotron JA-60 «Comfort»

7.2. Use of external sensors with the JA-60N The JA-60N detector can be used to wire external sensors which have contacts on their outputs. For example, it can be used to protect multiple doors or windows (see fig. 16). The built in magnetic se…

[Page 12] jablotron JA-60 «Comfort»

Alarm system JA-60 «COMFORT» — 12 — MDY51319 List of control panel programmable parameters Function sequence options factory d. note Enrolling of detectors and controllers 1 1& 6 scrolling, hold 2 to erase position, 3 all con…

[Page 13] jablotron JA-60 «Comfort»

Alarm system JA-60 «COMFORT» — 13 — MDY51319 8.2. Enrollment (teaching) of wireless items enter: 1 As a maximum 16 detectors and 8 controllers (remote controls & keypads) can be enrolled to the control panel. A wire- less sire…

[Page 14] jablotron JA-60 «Comfort»

Alarm system JA-60 «COMFORT» — 14 — MDY51319 where x represents the following functions (non split system): 0 Chime – triggered during the entrance delay (pre-alarm output) 1 Fire – triggered by a fire alarm (by a smoke or a gas d…

[Page 15] jablotron JA-60 «Comfort»

Alarm system JA-60 «COMFORT» — 15 — MDY51319 options: 2 8 1 reset enabled 2 8 0 reset disabled Factory default setting: reset enabled Note: if the Master or Service code is forgotten when the reset is disabled, the reset of the con…

[Page 16] jablotron JA-60 «Comfort»

Alarm system JA-60 «COMFORT» — 16 — MDY51319 8.15. Exit delay audible indication sequence: 3 3 x The exit delay can be indicated by the „beeping“ of the control panel (for the last five seconds, the beeping is faster). The audib…

[Page 17] jablotron JA-60 «Comfort»

Alarm system JA-60 «COMFORT» — 17 — MDY51319 8.20. Wireless siren alarm sequence: 3 8 x The wireless siren alarm function can be disabled with this parameter. This setting will have no influence on the outdoor siren chirp sounds func…

[Page 18] jablotron JA-60 «Comfort»

Alarm system JA-60 «COMFORT» — 18 — MDY51319 actions’ table a no splitting split system 0 no action no action 1 arm all arm all 2 disarm disarm all 3 partial arming arm A 4 partial arming arm B 5 disarm disarm A …

[Page 19] jablotron JA-60 «Comfort»

Alarm system JA-60 «COMFORT» — 19 — MDY51319 8.28. New service code setting sequence: 5 nSC nSC The Service Code can be used to enter the programming mode. A new Service Code must be entered twice in the se- quence to avoid an error. …

[Page 20] jablotron JA-60 «Comfort»

Alarm system JA-60 «COMFORT» — 20 — MDY51319 Note: enter a pause (F0) after the last digit of a number which is calling a mobile phone. This way the number will be called only once and the dialer will not check the line signals (some …

[Page 21] jablotron JA-60 «Comfort»

Alarm system JA-60 «COMFORT» — 21 — MDY51319 9.4. Dialing method sequence: 9 0 x Enter: 9 0 1 for tone dialing 9 0 0 for pulse dialing (this option is blocked for some countries) Note: this dialing method setting is also valid f…

[Page 22] jablotron JA-60 «Comfort»

Alarm system JA-60 «COMFORT» — 22 — MDY51319 10. To enable a remote computer to dial in When the user or installer wants to dial in to the installation from their JA-60U modem equipped computer or JA-60E keypad (see 15.), the fol…

[Page 23] jablotron JA-60 «Comfort»

Alarm system JA-60 «COMFORT» — 23 — MDY51319 12. Monitoring station communication setting This part of the manual is intended only for the use of specialists involved in monitoring. We recommend to use a com- puter equipped with Com…

[Page 24] jablotron JA-60 «Comfort»

12.2. Account code setting sequence: 02 This sequence is used for the alarm system identification by a Monitoring Station. The sequence structure is as follows: 02 x x x x xxxx – account code ( x are numbers from 0 to 9 or hexadecimals). Wh…

[Page 25] jablotron JA-60 «Comfort»

Alarm system JA-60 «COMFORT» — 25 — MDY51319 12.5. Phone number entering sequence: 06 Monitoring station modem phone numbers can be stored by entering the following sequence: 0 6 x x …. x F y xx…x — Monitoring Statio…

[Page 26] jablotron JA-60 «Comfort»

13. Monitoring station reporting codes table A two digit reporting code rc (00 to FFh) can be set for every event. If 00 is programmed as a report code, that event will not be reported. The major events group is marked with Rc. When formats 3…

[Page 27] jablotron JA-60 «Comfort»

Alarm system JA-60 “COMFORT” — 27 — MDY51319 13.1. Internal structure of Contact ID protocol The data in the CID protocol has following structure: XXXX 18 Q XYZ 01 CCC where XXXX is the account code of the installation, 18 is the c…

[Page 28] jablotron JA-60 «Comfort»

14. Personal Computer Interface with JA-60 The JA-60 system can be connected to a Personal Computer (PC) locally, using the PC-60A interface cable. It is also possible to dial into the system from a remote PC (or the JA-60E keypad) using the J…

[Page 29] jablotron JA-60 «Comfort»

“Dialing in” dialog of the Comlink Windows software 16. Recommended Professional installer basic rules If you install the system for a customer, you should follow these rules: • make a drawing of intended location of the items, keepi…

[Page 30] jablotron JA-60 «Comfort»

18. Possibilities to extend the system The JA-60 alarm system is a kit which can be tailor configured according to the size of the house or the needs of the user. See the structure of the system: (max. 1) CMS (max. 16) (max. 8) N 8.1 …

[Page 31] jablotron JA-60 «Comfort»

Alarm system JA-60 “COMFORT” — 31 — MDY51319 19. Overview of the JA-60 parts The following description includes the basic assortment of accessories. Jablotron is systematically introducing new and im- proved J etectors etic door detector…

[Page 32] jablotron JA-60 «Comfort»

JA-60G Gas leak detector — triggers a Fire alarm when any combustible gas is detected (natural gas, city gas, propane, butane etc.). The detector is powered directly form the AC power network and it wirelessly transmits information to the control …

[Page 33] jablotron JA-60 «Comfort»

built in buzzer. Illuminated keys can be covered with a closeable cover. The keypad has TWO-WAY communication with the control panel and it is enrolled as a controller (positions c1 to c8). Multiple JA-60F keypads can be enrolled to a single contro…

[Page 34] jablotron JA-60 «Comfort»

Telephone dialer module JA-60X — the control panel is available without the dialer (model JA-60K) or with the built in dialer (model JA- 60KX). The JA-60X dialer module can be easily installed to a JA-60K control panel as an after market accessory….

Report abuse

Libble takes abuse of its services very seriously. We’re committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we’ll investigate it and take the appropriate action. We’ll get back to you only if we require additional details or have more information to share.

Product:

Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron JA-60 in the language / languages: English as an attachment in your email.

The manual is 2 mb in size.

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

Это тоже интересно:

  • Converter 2 all4swap инструкция по применению
  • Conveen prep инструкция по применению салфетки
  • Contec pocket fetal doppler инструкция
  • Conveen prep coloplast инструкция салфетки
  • Conta flu инструкция по применению

  • Понравилась статья? Поделить с друзьями:
    0 0 голоса
    Рейтинг статьи
    Подписаться
    Уведомить о
    guest

    0 комментариев
    Старые
    Новые Популярные
    Межтекстовые Отзывы
    Посмотреть все комментарии