ELECTRONIC PRESSURE CONTROL
FOR SINGLEPHASE PUMP
Type BRIO 2000M
Owner’s manual
Summary of Contents for MPV BRIO 2000M
-
Page 1
ELECTRONIC PRESSURE CONTROL FOR SINGLEPHASE PUMP Type BRIO 2000M Owner’s manual… -
Page 2: Functional Parts
www.motor-pump-ventilation.com INSTRUCTIONS FOR USE FUNCTIONAL PARTS 1. RESET button 6. 1” male threaded connection outlet (By request, 1” female revolving nut) 2. Dry stop indicator 7. Line connection 3. Voltage indicator 8. 1” male threaded connection inlet (By request, 1” female revolving nut) 4.
-
Page 3: Safety Regulations
www.motor-pump-ventilation.com 1. FEATURES Brio 2000 is designed to automatize the starting and stopping operations of an electric pump with regard to a drop in pressure (opening of the taps) and to the stopping of the flow through the system (closing of the taps), respectively. Brio 2000 stops the pump when senses the lack of water flow, preventing it from any damaging dry operation.
-
Page 4: Installation
www.motor-pump-ventilation.com OPERATING INSTRUCTIONS The switch starts up the pump for 15 seconds once connected to the line. Any further pump starting occurs when the pre-set operating pressure value is reached, accordingly to the drop in pressure in the tubing when opening a tap. In the traditional water systems equipped with pressure switch and pressure tank, the pump stops when a certain pressure value is reached.
-
Page 5
www.motor-pump-ventilation.com ATTENTION: the check valve installed in the pump outlet and in the Brio 2000 inlet can cause some anomalies during the normal working of Brio 2000. Therefore it’s advisable avoiding its installation between the pump and Brio 2000. Attention: To modify the operating pressure adjustment it is necessary to take the cover away. -
Page 6
www.motor-pump-ventilation.com 220Vac 110Vac… -
Page 7
www.motor-pump-ventilation.com WARNING: TO ENSURE CORRECT WORKING OF THE BRIO 2000, MAXIMUM PUMP PRESSURE MUST BE AT LEAST 0,6 BAR HIGHER THAN BRIO 2000 OPERATING PRESSURE. 5. STARTING BRIO 2000 WARNING: whenever the level of the priming water is lower than the level of the water where the pump is placed, a suction line equipped with an antibackflow foot valve is absolutely essential. -
Page 8
www.motor-pump-ventilation.com… -
Page 9
www.motor-pump-ventilation.com… -
Page 10: Spare Parts
www.motor-pump-ventilation.com SPARE PARTS…

Originalgebrauchsanweisung
Elektronische Pumpensteuerung
Překlad originálního návodu k obsluze
Elektronické ovládání čerpadla
Translation of original operating instructions
Electronic pump control
Orijinal kullanım kılavuzunun çevirisi
Elektronik pompa kumandası
Traduction du mode d’emploi d’origine
Commande de pompe électronique
Превод на оригинално ръководство за експлоатация
Едно електронно управление
Traduzione istruzioni per l‘uso originali
Dispositivo elettronico di controllo
Traducerea instrucţiunii de utilizare originală
O comandă electronică a pompei cu
Traducción de las instrucciones de uso originales
Control electrónico
Originalni prijevod uputa za uporabu
Jedna električna upravna jedinica crpke
Vertaling van de oorspronkelijke gebruiksaanwijzing
Elektronische pompbesturing
Preklad originálneho návodu na použitie
Elektronický prístroj na riadenie čerpadla
Μετάφραση του πρωτοτύπου των οδηγιών χρήσης
ηλεκτρονικός διακόπτης
Prevod originalnih navodil za uporabo
Elektronsko upravljanje črpalke
Az eredeti használati útmutató fordítása
Egy elektronikus szivattyúvezérlés
Перевод оригинальной инструкции по эксплуатации
электронное устройство контроля
Tłumaczenie oryginalnej instrukcji obsługi
Elektroniczne sterowanie pomp
Переклад оригінальної інструкції по використанню
електронного управління насосом
Uni-Fitt
Пресс-контроль Uni-Fitt серии BRIO 2000-M/MT предназначен для автоматизации пуска и остановки электронасосов в системах водоснабжения и защиты их от «сухого хода». Технический паспорт.
Скачать
Pdf 625.72 Kb
Язык: RU